<output id="bwdac"></output>

    <td id="bwdac"></td>
    1. <pre id="bwdac"></pre><p id="bwdac"><strong id="bwdac"><xmp id="bwdac"></xmp></strong></p>

      <acronym id="bwdac"><strong id="bwdac"><xmp id="bwdac"></xmp></strong></acronym>
    2. <li id="bwdac"></li>

    3. <acronym id="bwdac"><label id="bwdac"><xmp id="bwdac"></xmp></label></acronym>
    4. Disposable Isolation Gown


      Description:

      Isolation Gown designed to protect health care patients and personnel from the transfer of microorganisms, body fluids and particulate material. Single use and disposable gown made of polypropylene. Product has been tested for chest and sleeves penetration by Hydrostatic Pressure Test and the results pass the AAMI different level requirements.

      Characteristic

      Specification

      Material

      PP+PE,SMS: "S" is short for "Spunbonded Polypropylene", "M" for "Melt Blown

      Color

      Blue/Green/Yellow/Purple

      Features

      Lightweight breathable gowns feature ties in back of neck and at waist for a secure, comfortable fit. Elastic cuffs at wrists keep the sleeves firmly in place and gather softly under gloves.

      Application

      Food process, Hospital ,Household , Laboratory,Hotel ,Painting and coating industry and so on

       


      Table 1:Gowns Type


       

      Type A

      Type B

      Type C

      Material

      PP+PE

      PET

      PP+PE with tap

      Colour

      Yellow

      Blue

      Yellow

      Classification

      AAMI PB70 Level 1

      AAMI PB70 Level 1

      AAMI PB70 Level 2

       

      Table 1:Gowns Type


      Ref. NO.

      Description

      Size

      Bag/Carton

      Bag Dimension(cm)

      Carton Dimension(cm)

      G.W.(KG)

      N.W.(KG)

      R120001

      Isolation Gown, Yellow, Level 1

      L

      10/100

      32*55

      58*38*28

      7.35

      6.28

      R120002

      Isolation Gown, Yellow, Level 1

      XL

      10/100

      32*55

      58*38*28

      8.95

      7.88

      R120003E

      Isolation Gown, Blue Level 1

      L

      10/100

      32*55

      42*28*34

      11.82

      12.5

      R120004E

      Isolation Gown, Blue Level 1

      XL

      10/100

      32*55

      42*28*34

      14.4

      15.1

      R120006

      Isolation Gown, Yellow, Level 2

      XL

      10/100

      32*55

      58*38*30

      8.4

      9.4

       

      The Guide to select gowns and other apparel.

      Safety starts well before the moment a clinician enters the patient’s room. The setting usage key and materials description as a guide to select right options for gowns in every situation.

      Setting usage guidelines

      The icons represented below should be used as a guideline in making gown selections for various needs and areas of your facility. Additionally, utilize the AAMI chart for the appropriate level gown.

      Materials descriptions

      Spunbond Polypropylene

      Standard, cost-effective and comfortable
      For basic infection control, this non-woven fabric bonds fibers together to form a single layer that is appropriate only for very minimal fluid exposure.

       

       

      SMS Material

      Balanced mix of protection and comfort
      Strong and breathable, Spunbond/Meltblown/Spunbond (SMS) is a multi-layer fabric composed of inner layers of meltblown polypropylene between outer layers of spunbond polypropylene that is ideal for extended wear. Light/medium weight SMS is appropriate for low amounts of fluid and heavy weight SMS may be appropriate for moderate contact with fluids.

       

       

      Coated Polypropylene (“Poly-coated”)

      Soft, spunbond polypropylene is coated with a layer of polyethylene (plastic) film.

       

       

      Polyethylene (Plastic) Film

      A single layer of polyethylene (plastic) film provides protection at an affordable cost.

       

       

      AAMI Level guide

      The Association for the Advancement of Medical Instrumentation (AAMI) standards are designed to help medical-device companies meet global standards for the safe use of medical devices. AAMI introduced the voluntary standard ANSI/AAMI PB70:2012, Liquid Barrier Performance and Classification of Protective Apparel and Drapes Intended for Use in Health Care Facilities,

      We're your source for AAMI compliant gowns. Choose the level you need, based on the green/orange/blue/purple color coding in the following chart.
       

      AAMI PB70 Guidelines

      ANSI/AAMI PB70 Barrier performance

      Test Method

      Test definition

      Requirement

      Anticipated fluid exposure

      AAMI Level 1

      Water resistance:
      Impact penetration AATCC 42

      AATCC 42
      Measures the resistance of fabrics to the liquid
      penetration of water by impact

      Water impact < 4.5 g

      Minimal
      fluid levels

      AAMI Level 2

      Water resistance:
      Impact penetration AATCC 42
      Water resistance:
      Hydrostatic pressure
      AATCC 27

      AATCC 42
      Measures the resistance of fabrics to the liquid
      penetration of water by impact
      AATCC 127
      Measures the resistance of fabrics to the liquid
      penetration of water by impact under constant and increasing hydrostatic pressure

      Spray impact < 1.0 g
      Hydrostatic Pressure
      > 20 cm

      Low fluid levels

      AAMI Level 3

      Water resistance:
      Impact penetration AATCC 42
      Water resistance:
      Hydrostatic pressure
      AATCC 27

      AATCC 42
      Measures the resistance of fabrics to the liquid
      penetration of water by impact
      AATCC 127
      Measures the resistance of fabrics to the liquid
      penetration of water by impact under constant and increasing hydrostatic pressure

      Spray impact < 1.0 g
      Hydrostatic pressure
      > 50 cm

      Moderate
      fluid levels

      AAMI Level 4

      ASTM F1671, Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage
      Penetration as a Test System

      ASTM F1671  Measures the resistance
      of materials used in protective clothing to penetration by blood borne pathogens using a surrogate microbe under conditions of continuous liquid contact.

      PASS

      High fluid and viral barrier levels

       

      Style guide

      Key features like wrist, neck and back style can vary from gown to gown. Use this style guide to understand the differences.

       

      Wrist style options

      Neck style options


      Back style option


      男人的天堂av高清在线
        <output id="bwdac"></output>

        <td id="bwdac"></td>
        1. <pre id="bwdac"></pre><p id="bwdac"><strong id="bwdac"><xmp id="bwdac"></xmp></strong></p>

          <acronym id="bwdac"><strong id="bwdac"><xmp id="bwdac"></xmp></strong></acronym>
        2. <li id="bwdac"></li>

        3. <acronym id="bwdac"><label id="bwdac"><xmp id="bwdac"></xmp></label></acronym>